Novec-1230 Fire Suppression System
Novec-1230 fluid revolutionized the fire protection market 15 years ago. Today, with more than 50,000 system installations in over 90 countries, and the approvals to back up our promises, we continue to move the industry forward with the purpose of delivering a solution that is designed to work now and for years to come. All clean agents are not the same. For example, HFC-227ea, sold under the FM-200® brand, is a hydrofluorocarbon (HFC) clean agent – which is a potent greenhouse gas. Due to their high global warming potentials (GWP), time is running out for HFCs, including FM-200. Novec 1230 fluid revolutionized the clean agent market in 2001 and now sets a new standard for sustainable clean agent fire suppression. Its unique dielectric properties and low vapor pressure yields design advantages to satisfy your top priority – protecting your assets. These advantages include ease of handling and the flexibility for higher pressure system innovation that is not practical for halons and HFCs. Specifying Novec 1230 fluid leverages these advances in fire suppression to protect your operations while eliminating future risks associated HFCs such as FM-200.
WHY WE SHOULD USE NOVEC-1230
- Fast
- Electrically non-conducting
- 5-day atmospheric lifetime
- Global warming potential <1
- Large margin of safety for occupied spaces
- Zero ozone depletion potential (ODP)
- Zero global warming potential (GWP)
25 BEST APPLICATION OF NOVEC-1230 FIRE SUPPRESSION SYSTEM
- Computer rooms
- Laboratories
- offshore Oil / gas exploration and production Facilities
- Telecommunication networks / centres / facilities
- Pharmaceutical and medical facilities
- Art galleries
- Comms Rooms
- Power generation & power storage
- Medical facilities.
- Record storage facilities
- Air traffic control centers
- Historical archive storage
- Control rooms
- Anechoic chambers
- Server rooms
- Libraries
- Telecommunication facilities
- Financial networks
- UPS Rooms
- Electric utilities
- DATA Centres
- Data centers
- Museums
- Marine vessels
- Medical equipment
6 COMMON PARTS OF Novec-1230 FIRE SUPPRESSION SYSTEM ?
- Control Unit
- Smoke Detection
- Heat Detection
- Suppression Cylinders
- Notification Devices
- Manual Pull Station
PREVENTIVE MAINTENANCE ( PM )OF Novec-1230
Before replacing batteries, disconnect AC power. Batteries should be replaced at least once
every 36 months, or as directed by the local Authority Having Jurisdiction. Do not install a
battery set whose open circuit voltage is less than 22 volts.
LEADING MANUFACTURERS AND BRANDS OF Novec-1230
BOOKS, WEBSITE AND OTHER REFERENCES:
- NFPA
- 3m novec-1230
- Ansul FM 200
- Kidde Novec-1230
- Janus Novec-1230
- ISOifDIS 14520: Gaseous Fire Exfinguishing Systems, International Standards Organiza – tion, Homebush, New South Wales, Australia, 2000.
- NFPA 2001: Standard on Clean Agent Fire Extinguishing Systems, 2000 Edition, NFPA, Quincy, MA, 2000.
- NFPA 2001: Standard on Clean Agent Fire Extinguishing Systems, 1996 Edition, NFPA, Quincy, MA, 1996.
WHAT ARE THE DETAILED PHYSICAL FORMULA OF NOVEC-1230 ?
Properties | Novec-1230 fluid |
---|---|
Chemical Formula | CF3CF2C(O)CF(CF3)2 |
Molecular Weight | 316.04 |
Boiling Point @ 1 atm | 49.2⁰C (120.6⁰F) |
Freezing Point | -108.0⁰C (-162.4⁰F) |
Critical Temperature | 168.7⁰C (335.6⁰F) |
Critical Pressure | 18.65 bar (270.44 psia) |
Critical Volume | 494.5 cc/mole (0.0251 ft3/lbm) |
Critical Density | 639.1 kg/m3 (39.91 lbm/ft3 ) |
Density, Sat. Liquid | 1.60 g/ml (99.9 lbm/ft3) |
Density, Gas @ 1 atm | 0.0136 g/ml (0.851 lbm/ft3 ) |
Specific Volume, Gas @ 1 atm | 0.0733 m3/kg (1.175 ft3/lb) |
Specific Heat, Liquid | 1.103 kJ/kg⁰C (0.2634 BTU/lb⁰F) |
Specific Heat, Vapor @ 1 atm | 0.891 kJ/kg⁰C (0.2127 BTU/lb⁰F) |
Heat of Vaporization @ boiling point | 88.0 kJ/kg (37.9 BTU/lb) |
Liquid Viscosity @ 0⁰C/25⁰C | 0.56/0.39 centistokes |
Vapor Pressure | 0.404 bar (5.85 psig) |
Relative Dielectric Strength, 1 atm (N2=1.0) | 2.3 |